What was found
DURING AN IMBV INSPECTION STRINGER 19 WAS FOUND CHAFED BELOW SRM LIMITS BETWEEN FRAMES 52R AND 53R. BLENDED THE CHAFE ON STRINGER 19R AND PERFORMED AN NDT INSPECTION. FABRICATED A REPAIR ANGLE, TWO SHIMS. REPAIRS DONE IAW EMB REPAIR STATEMENT IC2003-145/3093A. (M)