What was found
DURING AN MRB 4000 HOUR INSPECTION, TWO DENTS WERE FOUND NEAR FLOOR LEVEL ON CARGO FRAME 658.5 THAT WERE BEYOND SRM LIMITS. RECONTOURED THE FRAME AND PERFORMED AN EDDY CURRENT INSPECTION NO CRACK INDICATED. FABRICATED A REINFORCEMENT DOUBLER. INSTALLED, REPAIR DONE IAW SAAB REPAIR STATEMENT 340SDS007060, PARA 5. (M)