What was found
ABI - DURING AN MBV INSPECTION, THE BOTTOM FRAME UPPER FLANGE AT STATION 258, 17 INCHES FROM OUTBOARD HAS SINGLE ISOLATED CORROSION PIT. REMOVED CORROSION BY DRILLING A .215 DIAMETER HOLE. WET INSTALLED A NAS1241AD6 RIVET CUT TO LENGTH. REPAIR DONE IAW SAAB REPAIR STATEMENT 340SDS007185 PARA 2 DATED MAY 28, 2004. (M)