What was found
DURING AN MBV INSPECTION, 10 GOUGES WERE FOUND BELOW RIGHT STATIC PORT AT STRINGER 19. BLENDED GOUGES TO REMOVE DAMAGE. FABRICATED A DOUBLER. REPAIR DONE IAW EMB REPAIR STATEMENT IC2004-1453686 DATED AUGUST 10, 2004 AND IC2004-145/3710 DATED AUGUST 11, 2004. (M)