What was found
ABI - DURING AN IMBV INSPECTION, THE CENTER BEAM AT FRAME 20 WAS FOUND TO BE CORRODED BEYOND SRM LIMITS. REMOVED CORRODED CENTER BEAM. INSTALLED NEW BEAM IAW EMB SRM, SRM 145/1142 REV 26, 51-40-02 AND ETN EB 53-022R1. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ABI - DURING AN IMBV INSPECTION, THE CENTER BEAM AT FRAME 20 WAS FOUND TO BE CORRODED BEYOND SRM LIMITS. REMOVED CORRODED CENTER BEAM. INSTALLED NEW BEAM IAW EMB SRM, SRM 145/1142 REV 26, 51-40-02 AND ETN EB 53-022R1. (M)