What was found
DURING AN IMBV INSPECTION, THE LEFT OMEGA BEAM AT FRAME 20 WAS FOUND CORRODED BEYOND SRM LIMITS. PERFORMED A CUTOUT OF THE DAMAGED AREA AND TREATED THE BARE METAL EDGES. FABRICATED A REPAIR DOUBLER, FILLER TWO SHIMS AND BOTTOM PLATE. REPAIR DONE IAW EMB 145 SRM, SRM 145/1142 REV 26, CHAPTER 51-40-02. (M)