What was found
ABI - DURING AN IMBV INSPECTION, THE LEFT OMEGA BEAM BETWEEN FRAMES 33 AND 34 WAS FOUND CORRODED BEYOND SRM LIMITS. PERFORMED CUT OUT OF THE DAMAGED AREA. FABRICATED A FILLER, EXTERNAL ANGLE AND SHIMS. REPAIR DONE IAW EMB REPAIR STATEMENT IC2004-145/3835 DATED AUGUST 18, 2004. (M)