What was found
DURING AN IMBV INSPECTION, THE CENTER OMEGA BEAM BETWEEN FRAMES 33 AND 34 WAS FOUND CORRODED BEYOND SRM LIMITS. PERFORMED A CUT OUT OF THE DAMAGED AREA AND TREATED THE BARE METAL EDGES. FABRICATED A REPAIR DOUBLER, FILLER AND SHIMS. REPAIR DONE IAW EMB 145 SRM, SRM 145/1142 REV 26, CHAPTER 53-22-10 FIGURE 203 AND EMB REPAIR STATEMENT IC2003-145/3835 DATED AUGUST 18, 2004. (M)