What was found
DURING AN IMBV INSPECTION, THE CENTER OMEGA BEAM AT FS 25 WAS FOUND TO BE CORRODED BEYOND SRM LIMITS. REMOVED CORROSION BY MAKING A CUTOUT. FABRICATED A FILLER, DOUBLER AND TWO SHIMS. REPAIR DONE IAW EMB SRM, SRM 145/1142 REV 27, 53-22-10. (M)