What was found
ABI - DURING AN IMBV INSPECTION, THE SERVICE DOOR CENTER SILL WAS FOUND CORRODED BEYOND LIMITS. REMOVED DAMGAED SILL AND INSTALLED NEW SILL IAW EMB 145 SRM, SRM 145/1142 REV 27, CHAPTER 51-40-02. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ABI - DURING AN IMBV INSPECTION, THE SERVICE DOOR CENTER SILL WAS FOUND CORRODED BEYOND LIMITS. REMOVED DAMGAED SILL AND INSTALLED NEW SILL IAW EMB 145 SRM, SRM 145/1142 REV 27, CHAPTER 51-40-02. (M)