What was found
ABI - DURING AN IMBV INSPECTION, THE LEFT OMEGA BEAM AT FRAME 25 WAS FOUND CORRODED. PERFORMED A CUTOUT OF THE DAMGAED AREA. FABRICATED AN EXTERNAL ANGLE, FILLER AND TWO SHIMS. REPAIR DONE IAW EMB REPAIR STATEMENT IC2004-145/4061B DATED AUGUST 31, 2004. (M)