What was found
CORROSION WAS FOUND ON A PREVIOUS REPAIR ON THE LT OMEGA BEAM AT FRAME 20. REMOVED RPREVIOUS REPAIR. FABRICATED A DOUBLER ANGLE, FILLER, REINFORCEMENT PLATE AND 2 SHIMS. REPAIR DONE IAW EMB 145 SRM (SRM 145/1142, CHAPTER 53, REV 27) 53-21-10 ITEM 2 FIGURE 201 AND STANDARD SRM PRACTICES.