What was found
DURING AN MBV INSPECTION CORROSION WAS FOUND ON A PREVIOUS REPAIR TO THE LT OMEGA BEAM AT FRAME 20. REMOVED PREVIOUS REPAIR AND INSPECTION THE UNDERLYING BEAM, NO DAMAGE NOTED. FABRICATED AN EXTERNAL ANGLE, FILLER, SHIMS ND PLATE. REPAIR DONE IAW SRM. (SW21200501183)