What was found
DURING AN MBV INSPECTION THE LT OMEGA BEAM AT FRAME 20 WAS FOUND CORRODED. PERFORMED A CUT OUT OF THE DAMAGED AREA. FABRICATED A DOUBLER, FILLER AND 2 SHIMS. REPAIR DONE IAW SRM. (SW21200502478) (K)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING AN MBV INSPECTION THE LT OMEGA BEAM AT FRAME 20 WAS FOUND CORRODED. PERFORMED A CUT OUT OF THE DAMAGED AREA. FABRICATED A DOUBLER, FILLER AND 2 SHIMS. REPAIR DONE IAW SRM. (SW21200502478) (K)