What was found
ABI - DURING AN INSPECTION, THE LEFT OMEGA BEAM BETWEEN FRAMES 24 AND 25 WAS FOUND CORRODED. PERFORMED CUT OUT OF THE OMEGA BEAM TO REMOVE THE CORROSION. FABRICATED AN EXTERNAL ANGLE, FILLER AND TWO SHIMS. REPAIR DONE IAW EMB 145 SRM, SRM EMB 145/1142 REV 29, CHAPTER 53-22-10 FIG 202. (M)