What was found
ABI - DURING AN MBV INSPECTION, THE GALLEY CENTER BEAM AT FRAME 20 WAS FOUND TO BE CORRODED. REMOVED THE CORRODED CENTER BEAM. INSTALLED NEW BEAM IAW EMB SRM (SRM-145/1142 REV 29) CHAPTER 51-40-02. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ABI - DURING AN MBV INSPECTION, THE GALLEY CENTER BEAM AT FRAME 20 WAS FOUND TO BE CORRODED. REMOVED THE CORRODED CENTER BEAM. INSTALLED NEW BEAM IAW EMB SRM (SRM-145/1142 REV 29) CHAPTER 51-40-02. (M)