What was found
THE CENTER OMEGA BEAM AT FRAME 25 WAS FOUND TO BE CORRODED. REMOVED THE CORROSION BY MAKING A CUT OUT. FABRICATED A DOUBLER, FILLER AND SHIMS. REPAIR DONE IAW SRM. (K)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
THE CENTER OMEGA BEAM AT FRAME 25 WAS FOUND TO BE CORRODED. REMOVED THE CORROSION BY MAKING A CUT OUT. FABRICATED A DOUBLER, FILLER AND SHIMS. REPAIR DONE IAW SRM. (K)