What was found
ABI - THE CENTER OMEGA BEAM AT FRAME 27 WAS FOUND CORRODED. PERFORMED A CUT OUT OF BEAM TO REMOVE THE CORROSION. FABRICATED AN EXTERNAL DOUBLER, FILLER AND TWO SHIMS. REPAIR DONE IAW EMB 145 SRM, SRM EMB145/1142 REV 29, CHAPTER 53-00-10, FIG 203. (M)