What was found
FOUND DURING CPCP INSPECTION, GALLEY FLOOR SUPPORT CORRODED AT FRAME 22. INSTALLED NEW GALLEY FLOOR SUPPORT AT FRAME 22 IAW SRM 51-40-02. AIRCRAFT WAS RETURNED TO SERVICE. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND DURING CPCP INSPECTION, GALLEY FLOOR SUPPORT CORRODED AT FRAME 22. INSTALLED NEW GALLEY FLOOR SUPPORT AT FRAME 22 IAW SRM 51-40-02. AIRCRAFT WAS RETURNED TO SERVICE. (M)