What was found
ABI - THE SERVICE DOOR CENTER SILL WAS FOUND CORRODED. REMOVED THE SERVICE DOOR SILL AND INSTALLED SERVICEABLE SILL IAW EMB 145 SRM, SRM EMB145/1142 REV 30, CHAPTERS 51-40-02 AND 51-20-01. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ABI - THE SERVICE DOOR CENTER SILL WAS FOUND CORRODED. REMOVED THE SERVICE DOOR SILL AND INSTALLED SERVICEABLE SILL IAW EMB 145 SRM, SRM EMB145/1142 REV 30, CHAPTERS 51-40-02 AND 51-20-01. (M)