What was found
AIRCRAFT WAS REMOVED FROM SERVICE. DURING MBV INSPECTION THE BAGGAGE DOOR OPENING LOWER CENTER SILL WAS FOUND CORRODED. REMOVED AND REPLACE WITH NEW SILL PN 145-25480-603 IAW EMB 145 SRM 51-40-02 AND 51-20-03. AIRCRAFT RETURNED TO SERVICE.