What was found
DURING HMBV INSPECTION, FOUND CENTER OMEGA BEAM AT FRAME 24 CORRODED BEYOND MANUAL LIMITS UNDER CARBON CROSSBEAM. OMEGA BEAM REPAIRED IAW EMBRAER SRM 53-00-10 FIG 203. AIRCRAFT WAS RETURNED TO SERVICE.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING HMBV INSPECTION, FOUND CENTER OMEGA BEAM AT FRAME 24 CORRODED BEYOND MANUAL LIMITS UNDER CARBON CROSSBEAM. OMEGA BEAM REPAIRED IAW EMBRAER SRM 53-00-10 FIG 203. AIRCRAFT WAS RETURNED TO SERVICE.