What was found
DURING MAINTENANCE BASE VISIT FOUND THE CEILING EMERGENCY LIGHT AT ROW 11 TO BE WORKING INTERMITTENT. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED THE CEILING EMERGENCY LIGHT ASSEMBLY IAW EMB AMM 33-50-08. THE OPERATIONAL CHECK WAS GOOD. THE AIRCRAFT WAS RETURNED TO SERVICE.