Service difficulty report · Pump · Emb EMB145LR

Difficulty date
January 1, 2012
Submitted
January 5, 2012
Operation
Air carrier
Aircraft
N620AE
Make and model
Emb EMB145LR
Aircraft serial
145102
Aircraft time
30,397 hours, 27,808 cycles
Part
Pump
Part number
MPEV30086
Part serial
MX658440
Condition
Failed
Location
Hydraulic Sys
Stage of operation
CR
How discovered
O
Nature of condition
O
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

ON FLIGHT 3591 THE CREW REPORTED THE HYDRAULIC 2 PUMP FAILED/ELEC HYD 2 PUMP OPERATIONAL AT 2800 PSI IN AMBER QTY. THE CREW ELECTED TO DIVERT. THE AIRCRAFT LANDED WITHOUT INCIDENT. THE AIRCRAFT WAS REMOVED FROM SERVICE. FOUND BROKEN LINE ON ELECTRIC HYD PUMP. REMOVED AND REPLACED THE LINE 29-10-04. LEAK CHECK GOOD. ALSO AFTER RUNNING ELECTRIC PUMP MASS AMOUNT OF SMOKE FROM EXHAUST VENT. REMOVED AND REPLACED PUMP IAW EMB 145 AMM 24-10-04. THE AIRCRAFT WAS RETURNED TO SERVICE.

More about the Emb EMB-145LR