As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING MAINTENANCE INSPECTION FOUND THE EMERGENCY FLOOR STRIP LIGHTS NR 1, 2, 3 INOPERATIVE. AIRCRAFT REMOVED FROM SERVICE. REMOVED AND REPLACED THE INVERTER 2 AND 3 IAW EMB AMM 33-50-11. THE OPERATIONAL CHECK WAS GOOD. THE AIRCRAFT WAS RETURNED TO SERVICE.