As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING MAINTENANCE INSPECTION FOUND THE EMERGENCY FLOOR LIGHT STRIPS NR 4 AND NR 5 INOPERABLE. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED THE NR 5 POWER INVERTER IAW EMB 145 AMM 33-50-11. THE OPERATIONAL CHECK WAS GOOD. THE AIRCRAFT WAS RETURNED TO SERVICE.