RT BEAM IN GALLEY AREA HAS CORROSION AT FR 23. REPAIRED BEAM IAW EO EM-53MR-2035.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
RT BEAM IN GALLEY AREA HAS CORROSION AT FR 23. REPAIRED BEAM IAW EO EM-53MR-2035.