What was found
THE CREW REPORTED A BLEED TWO LEAK INDICATION AFTER TAKEOFF AT 900 FT AGL. THE CREW PERFORMED EMERGENCY PROCEDURES. BLEED 2 LEAK INDICATION EXTINGUISHED AFTER APPROX. 30 SEC. BURNED OFF FUEL BEFORE LANDING. NO OVERWEIGHT LANDING. THE ACFT WAS REMOVED FROM SERVICE. R & R THE FAN AIR VALVE THERMOSTAT, PN: 8166248, SN: 200105088 AND LEAKING GROUND BLEED AIR CONNECTION VALVE IAW AMM 36-10-02, AND 36-11-06. THE OPS CHECK WAS GOOD IAW AMM 36-00-00. THE ACFT WAS RETURNED TO SERVICE.