As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
HYDRAULIC 1, LOW QUANITY MESSAGE ON EICAS. NR 1 EDP LEAKING. R & R NR 1 EDP IAW AMM 29-10-03. PS-1 CHECK ACCOMPLISHED 11-6-13. ACCOMPLISHED OIL CHECK IAW OIL SERVICE CHECK CARD. FOUND OXYGEN PRESSURE TO BE 1800 PSI SERVICED TO 1850 PSI TEMP 65. IAW AMM 35-12-00.