What was found
DURING 3C CHECK FOUND FLOORBEAM BS 280 HAS A CRACK APPROXIMATELY 3 INCHES IN LENGTH WITH CORROSION SURROUNDING IT, OTBD OF LBL 9. REPAIRED FLOORBEAM & RESTORED TOPCOAT IAW SRM 51-42-06 & 51-25-00.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.