What was found
NR 4 EMERGENCY LIGHT STRIP WIRE INSULATION TORN. REPAIRED USING HEAT SHRINK RNF-100-1/8-WH & RNF-100-3/16-WH IAW SWPM 20-21-00 STEP 7.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
NR 4 EMERGENCY LIGHT STRIP WIRE INSULATION TORN. REPAIRED USING HEAT SHRINK RNF-100-1/8-WH & RNF-100-3/16-WH IAW SWPM 20-21-00 STEP 7.