What was found
ELT IS FAILING THE OPS CHECK IAW WORK CARD 25-700-07. BIT TEST INDICATES A THREE FLASH FAULT CODE. R & R ELT TRANSMITTER ASSEMBLY IAW AMM 25-61-01. R & R ELT TRANSMITTER CABLE IAW SWPM 20-21-00. OPS CHECKED GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ELT IS FAILING THE OPS CHECK IAW WORK CARD 25-700-07. BIT TEST INDICATES A THREE FLASH FAULT CODE. R & R ELT TRANSMITTER ASSEMBLY IAW AMM 25-61-01. R & R ELT TRANSMITTER CABLE IAW SWPM 20-21-00. OPS CHECKED GOOD.