What was found
CLIMBING THROUGH 7000 FT, RECEIVED A NR 2 BLEED OVERTEMP IN ICING CONDITIONS. REMOVED AND REPLACED PRECOOLER TEMP SENSOR IAW MM 36-20-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLIMBING THROUGH 7000 FT, RECEIVED A NR 2 BLEED OVERTEMP IN ICING CONDITIONS. REMOVED AND REPLACED PRECOOLER TEMP SENSOR IAW MM 36-20-01.