As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
BAGG SMOKE WARNING CAME ON JUST PRIOR TO LANDING, BAGG EXTINGUISHER WAS PRESSED WARNING REMAINED ON CFR CALLED. TRANSFERRED TO NRWC 660-MIA-01582. R & R BAGG COMPARTMENT HIGH RATE & METERING EXTINGUISHER BOTTLE IAW AMM 26-23-01. R & R BAGG SMOKE TEST RELAY K0629 IAW AMM 20-13-02.