What was found
FLOOR EMERGENCY LIGHT SECTIONS 4 & 5, WING EMERGENCY EXIT SIGNS INOPERATIVE. R & R NR 5 EMERGENCY LIGHT INVERTER IAW AMM 33-50-11 & NR 3 BATTERY PACK & CHARGER IAW AMM 33-50-04. OPERATIONS CHECKED OK PN 11-0049 & SN 20100.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOOR EMERGENCY LIGHT SECTIONS 4 & 5, WING EMERGENCY EXIT SIGNS INOPERATIVE. R & R NR 5 EMERGENCY LIGHT INVERTER IAW AMM 33-50-11 & NR 3 BATTERY PACK & CHARGER IAW AMM 33-50-04. OPERATIONS CHECKED OK PN 11-0049 & SN 20100.