As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
NR 1 BLEED VALVE CLOSED EICAS MESSAGE IN FLIGHT. CAME ON AT APPROX 10,000 FT IN CLIMB POWER. STAYED ON UNTIL TOUCHDOWN. COMPLIED WITH ALL EMERGENCY & ABNORMAL PROCEDURES THAT WERE APPLICABLE. R & R NR 1 ENGINE BLEED AIR VALVE IAW 36-11-05. OPS CHECKED GOOD.