As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
SERVICE DOOR EXTERNAL EMER LIGHT INOPERATIVE. R & R SERVICE DOOR EXTERNAL EMER LIGHT LAMP IAW TASK 33-50-10-000-801-A & TASK 33-50-10-400-801-A,OPERATION CHECK, NO FIX. CONFIRMED POWER IS GETTING TO ASSEMBLY THROUGH QUICK DISCONNECT WIRES. FOUND PIN PUSHED OUT AT PLUG P7198. REINSTALLED PIN IAW SWPM 20-50-0. OPERATIONS CHECKED GOOD IAW MM 33-50-00. MEL RESTORED & PLACARD REMOVED.