What was found
CREW UNABLE TO OPEN MAIN DOOR FROM INSIDE ACFT. DOOR HAD TO OPENED BY RAMP FROM OUTSIDE. REPEAT WRITE UP IAW PAGE 3595075. REPOSITIONED INTERNAL DOOR HANDLE ON TORQUE TUBE IAW AMM 52-11-01. NORMAL OPERATION NOTED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CREW UNABLE TO OPEN MAIN DOOR FROM INSIDE ACFT. DOOR HAD TO OPENED BY RAMP FROM OUTSIDE. REPEAT WRITE UP IAW PAGE 3595075. REPOSITIONED INTERNAL DOOR HANDLE ON TORQUE TUBE IAW AMM 52-11-01. NORMAL OPERATION NOTED.