What was found
HYD 2 LOW QTY ADVISORY IN FLIGHT, ABOUT 20 - 30 MINUTES LATER HYD 2 PUMP FAIL MSG. POST FLIGHT SHOWS HYD FLUID COATING INSIDE NR 2 WW. R & R NR 2 ENG DRIVEN PUMP IAW AMM 29-10-03. RAN ENGS LEAK & OPERATIONS CHECKED GOOD, NO DEFECTS NOTED.