What was found
ON GEAR RETRACTION BRAKE OVERHEAT MSG ON EICAS. LT OTBD SHOW TOP OF YELLOW. USING DIGITAL THERMOMETER FOUND TEMP OK. R & R NR 1 BRAKE TEMP SENSOR. OPERATIONS CHECKED GOOD IAW AMM 32-47-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ON GEAR RETRACTION BRAKE OVERHEAT MSG ON EICAS. LT OTBD SHOW TOP OF YELLOW. USING DIGITAL THERMOMETER FOUND TEMP OK. R & R NR 1 BRAKE TEMP SENSOR. OPERATIONS CHECKED GOOD IAW AMM 32-47-01.