What was found
AFTER LANDING EICAS PRESENTED A BAGG SMOKE INDICATION. FOLLOWED AOM PROCEDURES, MEMORY ITEMS & PRESSED BAGG EXTINGUISHER BUTTON. NO VISUAL INDICATION OF FIRE. EMER DECLARED. R & R METERING FIRE BOTTLE FOR CARGO COMPARTMENT IAW AMM 26-23-01. OPERATIONS CHECKED GOOD IAW AMM 26-15-00. R & R BAGGAGE COMPARTMENT SMOKE DETECTION SENSORS IAW 26-15-01. OPERATIONS CHECKED GOOD IAW AMM 26-15-00. CARGO AREA SMOKE DETECTOR PN 473597-13, SN 1032 & 3041.