What was found
HAD BLEED 2 LEAK INFLIGHT EPCT, AOM FOLLOWED, HAD TO PERFORM PRECAUTIONARY ENG SHUTDOWN. RAN E2 IAW EMB FOUND NO LEAKS IN PYLON. INSPECTED BLEED SYS IAW ETN EM 36-048 FOUND LEAK AT JOINT NR 4. R & R O RINGS IAW AMM 36-11-10. NO CMC OR EICAS MSGS.