As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING MBV INSPECTION QA FOUND FRAME 65 SHEAR CLIP CORRODED AT LOWER FWD CORNER OF CARGO DOOR CUT OUT & CHAFE BETWEEN STRINGER 14L & 15L. ACFT WAS REMOVED FROM SERVICE FOR MBV INSPECTION & WILL BE RETURNED TO SERVICE AFTER MBV INSPECTION. PERFORMED PERMANENT REPAIR TO FRAME 65 SHEAR CLIP IAW ERS-EM-53MR-787. SHEAR CLIP 145-25178-001.