What was found
EMERGENCY LIGHTS OPERATIONAL CHECK FAILED. R & R NR 2 & 3 BATTERY POWER SUPPLY, BATTERY & CHARGER, FOR EMER LIGHTS SYS IAW AMM 33-50-04. OPERATIONAL CHECKED GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
EMERGENCY LIGHTS OPERATIONAL CHECK FAILED. R & R NR 2 & 3 BATTERY POWER SUPPLY, BATTERY & CHARGER, FOR EMER LIGHTS SYS IAW AMM 33-50-04. OPERATIONAL CHECKED GOOD.