What was found
INTERIOR EMER LIGHTS PULSATE ON & OFF. DEFERRED IAW MEL 33-32. REPLACED RELAY K135 ON PCB5 JB-11 IAW MM 24-06-11 & CMM 24-06-00. ALL OPERATIONAL CHECKS GOOD. EMER LIGHTING SYS OPERATIONS CHECKED GOOD. MEL ITEM RESTORED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INTERIOR EMER LIGHTS PULSATE ON & OFF. DEFERRED IAW MEL 33-32. REPLACED RELAY K135 ON PCB5 JB-11 IAW MM 24-06-11 & CMM 24-06-00. ALL OPERATIONAL CHECKS GOOD. EMER LIGHTING SYS OPERATIONS CHECKED GOOD. MEL ITEM RESTORED.