What was found
FOUND THE FLOOR EMER LIGHT INOPERATIVE AT THE LAVATORY DOOR. R & R FLOOR EMER LIGHT STRIP BY LAVATORY DOOR IAW AMM 33-50-12. OPERATIONS CHECKED GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND THE FLOOR EMER LIGHT INOPERATIVE AT THE LAVATORY DOOR. R & R FLOOR EMER LIGHT STRIP BY LAVATORY DOOR IAW AMM 33-50-12. OPERATIONS CHECKED GOOD.