What was found
FRAME CLIP 65 IS CRACKED BETWEEN STRINGERS 7L & 8L. CRACK IS 1.5 INCHES IN LENGTH. FABRICATED & INSTALLED SHEAR CLIP AT FRAME 65 IAW ERS EM-5300-1070 & SRM 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FRAME CLIP 65 IS CRACKED BETWEEN STRINGERS 7L & 8L. CRACK IS 1.5 INCHES IN LENGTH. FABRICATED & INSTALLED SHEAR CLIP AT FRAME 65 IAW ERS EM-5300-1070 & SRM 51-40-02.