What was found
DURING DESCENT PRONOUNCED ELEC BURNING SMELL IN COCKPIT & FWD CABIN, NO VISIBLE FUMES OR SMOKE, LASTED THROUGHOUT LANDING. COMPLIED WITH ETN-EM-72-034 UNDER CONFIGURATION OF ITEM 5. IAW 53-10-02 INSPECTED PACK 2 AIR CONDITION DUCTS, RECIRC FANS & GASPER FAN. NO ODOR OR DAMAGED NOTED. ACFT OK FOR SERVICE. REF ITEM 1 PREVIOUS LOG PAGE 3743327 ITEM 1 MOC REQUESTING FURTHER INSPECTION OF COCKPIT ELEC SYS. VISUALLY INSPECTED COCKPIT ELEC EQUIPMENT & SURROUNDINGS. NO SIGNS OF HEAT DAMAGE, SMELL OF SMOKE FOUND. FOUND SMELL OF ELEC SMOKE ON FIRST OFFICER`S OFFICERS FLASHLIGHT. R & R FIRST OFFICER`S FLASHLIGHT IAW EMB AMM 33-50-16-14.