What was found
DURING IMBV INSPECTION, QA FOUND A SHEAR CLIP CRACKED AT FRAME 68 BETWEEN STRINGERS 6L - 7L. ACFT WAS REMOVED FROM SERVICE FOR IMBV INSPECTION & WILL BE RETURNED TO SERVICE AFTER IMBV INSPECTION. REPAIRED SHEAR CLIP IAW ERS-EM-53MR-1191. REPAIR MATERIALS, SHEAR CLIP PN'S 140-04102-601 & 140-04102-603.