What was found
DURING MBV INSPECTION, FOUND A TOTAL OF 5 DENTS BETWEEN FRAME 24 & 28, BETWEEN STRINGER 15L - 17L. ACFT WAS REMOVED FROM SERVICE FOR MBV INSPECTION & WILL BE RETURNED TO SERVICE AFTER MBV INSPECTION. PERFORMED PERMANENT REPAIR ON DENTS 4 & 5 IAW ERS-EM-53MR-1329 STEPS 1 - 18. REPAIR MATERIALS, DOUBLER 2024-T3, 0.063, FILLER 2024-T3, 0.050. DENTS 1, 2 & 3 WERE ACCEPTED AS IS IAW ERS-EM-53MR-1329 STEPS 19 - 25. THESE DENTS WERE ENTERED IN ADL 6240089 & 6240090.